| Sl No | Quantity Measured / Instrument | Range/Frequency | *Calibration Measurement Remarks Capability (±) | Remarks |
|---|---|---|---|---|
| I | PRESSURE INDICATING DEVICES | |||
| 1 | Pressure-Hydraulic Dial Pressure Gauge,Digital Pressure Gauges, Pressure Calibrator, Pressure Transducers and Pressure Transmitter with Indicators | 2 bar to 690 kg/cm | 0.017% rdg. | Using Hydraulic Dead Weight Tester based on DKD-R6-1 |
| 2 | Pressure-Hydraulic Dial Pressure Gauge,Digital Pressure Gauges, Pressure Calibrator, Pressure Transducers and Pressure Transmitter with Indicators | 0 bar to 690 bar | 0.11% rdg. | Using Digital Pressure Calibrator 0-700 & Hydraulic Pump based on DKD-R6:1 |
| 3 | Pressure-Hydraulic Dial Pressure Gauge,Digital Pressure Gauges, Pressure Calibrator, Pressure Transducers and Pressure Transmitter with Indicators | 0 bar to 30 bar | 0.06% rdg | Using Pneumatic Pump & Digital Pressure Calibrator based on DKD-R6-1 |
| II | DIMENSION (BASIC MEASURING INSTRUMENT, GAUGE ETC.) | |||
| 1 | Vernier Calipers | 0 to 150 mm 0 to 300 mm. 300 mm to 1000 mm | 8 μm 12 μm 19 μm | Using 'K' & 'O Grade' Slip Gauge Set |
| 2 | External Micrometer | 0 to 25 mm | 1.9 µm | Using 'K' & 'O Grade' Slip Gauge Set |
| III | UTM, TENSION CREEP AND TORSION TESTING MACHINE | |||
| 1 | Verification of Uniaxial Testing Machine | Compression: 0.25 KN to KN 1 kN to 100 kN | 0.3% 0.2% | Using "0" Class load cells with digital indicator as per IS 1828 (Part-1) |
| Tension: 1 kN to 100 kN | 0.2% | |||
| IV | SPEED AND ACCELERATION | |||
| 1 | Tachometer | 60 rpm to 1000 rpm 1000 rpm to 3000 rpm 3000 rpm to 5000 rpm | 1.6% rdg. 1.1 % rdg. 1.1% rdg. | Using Digital Tachometer By Comparison Method |
| V. | WEIGHING SCALE AND BALANCE | |||
| 1. | Non-Automatic Weighing Balance/Scale d = 0.01 mg d= 0.001 g d = 0.01 g | 0 to 200 g 0 to 1 kg 0 to 5 kg | 0.06 mg 4 mg 20 mg | UsingE1/E2/F1Accuracy Class Standard Weights as per OIML-R-76-1 |
| VI. | WEIGHTS | |||
| 2. | Calibration of Weights Class F1 Accuracy and Coarser |
1mg 2mg 5mg 10mg 20mg 50mg 100mg 200mg 500mg 1g 2g 5g 10g 20g 50g 100g 200g | 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.03 mg 0.04 mg 0.07 mg | Using Weights of Accuracy Class E1 and balance of readability 0.01 mg based on OIMLR111-1ABBA Cycle Substitution Method |
| Class F1 Accuracy 500g and Coarser | 500g 1kg | 0.93 mg 1mg | Using Weights of Accuracy Class E1 and balance of readability 0.01 mg based on OIMLR111-1ABBA Cycle Substitution Method | |
| Class F2 Accuracy and Coarser | 2 kg 5 kg | 8.3 mg 12.2 mg | Using Weights of Accuracy Class F1 and balance of readability 0.01 g based on gb OIMLR111-1ABBA Cycle Substitution Method | |
| VII | VOLUME | |||
| 1 | Micro Pipette/ Piston Pipette | 10 μl to100 μl | 2.60 μl | Using Digital Balance with d: 0.01 mg of Cap. 220 g and Distilled Water of known Density As per ISO 8655-6 |
| 2 | Glass Pipette | 1 ml to10 ml > 10 ml to100 ml | 2.30 μl 2.32 μl | Using Digital Balance with d: 0.01 mg of Cap. 220 g and Distilled Water of known Density as per ISO 4787 |
| 3 | Measuring Cylinders | > 100 ml to 200 ml > 200 ml to 1000 ml | 3 μl 13μl | Using Digital Balance with d: 1 mg of Cap. 1 kg and Distilled Water of known Density as per ISO 4787 Using Digital Balance with d: 10 mg of Cap. 5 kg and Distilled Water of known Density as per ISO 4787 |